Moisture Analyzer is a new type of rapid moisture testing equipment, sub-detection equipment. The ring-shaped halogen lamp ensures that the sample is heated evenly and the operation is simple and accurate. Halogen Moisture Analyzer measures the weight of the sample. Halogen Moisture Analyzer uses the halogen heating method of the ring tube to rapidly dry the sample. During the drying process, the moisture analyzer continuously measures and immediately displays the lost moisture content of the sample. After the drying process is completed, finally The measured moisture content is locked out.
Rapid moisture meter maintenance:
1. Use a finger to press the key during the use of the quick moisture analyzer to avoid using nails, and it is forbidden to use sharp hard objects.
2. The cover of the quick moisture analyzer should be lightly lifted.
3, the minimum sample size must be greater than 0.5 grams.
4. When the quick moisture analyzer is in standby state, it can be used without preheating.
5. The quick moisture analyzer should clean the sample tray before putting the sample, and the sample tray holder should be used at any time to prevent the hot sample tray from being burned.
6. The last display state of the test will remain on the screen until you press the TARE key. The second time after the test should be as soon as possible to prevent the loss of moisture.
7. Before using the Halogen Moisture Analyzer, check whether the power supply voltage is consistent with the requirements of the Halogen Moisture Analyzer. Check whether the socket and device plugs are intact. Do not use if damaged. Please turn off the main power switch before work or without the instrument for a long time. If there is no main switch, remove the power plug and place it next to the instrument.
Rapid moisture meter maintenance:
1. Use a finger to press the key during the use of the quick moisture analyzer to avoid using nails, and it is forbidden to use sharp hard objects.
2. The cover of the quick moisture analyzer should be lightly lifted.
3, the minimum sample size must be greater than 0.5 grams.
4. When the quick moisture analyzer is in standby state, it can be used without preheating.
5. The quick moisture analyzer should clean the sample tray before putting the sample, and the sample tray holder should be used at any time to prevent the hot sample tray from being burned.
6. The last display state of the test will remain on the screen until you press the TARE key. The second time after the test should be as soon as possible to prevent the loss of moisture.
7. Before using the Halogen Moisture Analyzer, check whether the power supply voltage is consistent with the requirements of the Halogen Moisture Analyzer. Check whether the socket and device plugs are intact. Do not use if damaged. Please turn off the main power switch before work or without the instrument for a long time. If there is no main switch, remove the power plug and place it next to the instrument.