Summary
    This instrument is designed and made as per the national standard of People's Republic of China GB/T265 Petroleum products-Determination of kinematic viscosity and calculation of dynamic viscosity, GB/T 11137 Black petroleum products-Determination of kinematic viscosity(reverse-flow method) and calculation of dynamic viscosity and GB/T 1995 Petroleum products-Calculation of viscosity index. It is used to determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
Â
I. Main technical features
1. Multifunctional. It can determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
2. Micro-processor control and colored LCD technology. Chinese-English bilingual menu. GUI touch screen. Easy to operate.Â
3. Advanced digital control and display. Automatic kinematic viscosity determination
4. It can test 2 samples at a time. The parameters such as temperature, time, coefficient of capillary viscometer tube can be inputted in or displayed on the screen.Â
5. New-type temperature sensor. The temperature resolution is 0.01ºC. Temperature control precision is ±0.05ºC. 6. It can save 99 coefficients of capillary viscometer.
Â
II. Main technical specifications
1.Capacity of bath:    240mm×280mm
2.Temperature range:    Ambient to 100ºC
3.Temperature resolution:    0.01ºC
4.Temperature control precision:  ±0.05ºC
5. Timing precision:   ±0.1s
6. Display:   5.6 inch colored LCD
7. Sample amount:   2 samples
8. Power supply:   AC(220±10%)V, 50Hz±1Hz
9. Maximum power consumption:  750W
10. Working environment:   Ambient temp.:(15~35)ºC ,RH <85%
11. Dimension:   535mm×440mm×550mm
12. Net weight:   23kg
Â
SYD-265-3 Capillary Viscometer Washer
Summary
    The instrument is designed and made specially for washing the capillary viscometers, which are used for testing petroleum products. It can be used to wash glass capillary viscometer of various types, such as Pinkevitch viscometer, Ubbelohde viscometer, Cannon-Fenske routine viscometer, Cannon-Fenske opaque viscometer. It is high-efficient and time saving especially for the capillary viscometers, which are used for testing heavy oil with high viscosity. Â
    It adopts micro-controller control technology, program control, automatic washing. It needs less solvent oil and it is convenient, efficient. It can be widely used in the enterprises producing and using petroleum products, colleges and universities, and scientific research institutes and so on, where capillary viscometer are used.
Â
I. Main technical specifications
1. Power supply: AC 220V±10%, 50 Hz
2. Maximum power consumption: 700 W
3. Water bath temperature control range: Ambient to 80 ºC
4. Ambient temperature: Room temperature~35ºC
5. Relative humidity: ≤85%
6. Dimension of washer: 320mm×300mm×500mm ( excluding the aspirator )
7. Net weight of washer: 10Kg (excluding the aspirator)
SYD-265B-1 Kinematic viscosity / Reverse-flow viscosity / Viscosity indexÂ
Summary
    This instrument is designed and made as per the national standard of People's Republic of China GB/T265 Petroleum products-Determination of kinematic viscosity and calculation of dynamic viscosity, GB/T 11137 Black petroleum products-Determination of kinematic viscosity(reverse-flow method) and calculation of dynamic viscosity and GB/T 1995 Petroleum products-Calculation of viscosity index. It is used to determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
Â
I. Main technical features
1. Multifunctional. It can determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
2. Micro-processor control and colored LCD technology. Chinese-English bilingual menu. GUI touch screen. Easy to operate.Â
3. Advanced digital control and display. Automatic kinematic viscosity determination
4. It can test 2 samples at a time. The parameters such as temperature, time, coefficient of capillary viscometer tube can be inputted in or displayed on the screen.Â
5. New-type temperature sensor. The temperature resolution is 0.01ºC. Temperature control precision is ±0.05ºC. 6. It can save 99 coefficients of capillary viscometer.
Â
II. Main technical specifications
1.Capacity of bath:    240mm×280mm
2.Temperature range:    Ambient to 100ºC
3.Temperature resolution:    0.01ºC
4.Temperature control precision:  ±0.05ºC
5. Timing precision:   ±0.1s
6. Display:   5.6 inch colored LCD
7. Sample amount:   2 samples
8. Power supply:   AC(220±10%)V, 50Hz±1Hz
9. Maximum power consumption:  750W
10. Working environment:   Ambient temp.:(15~35)ºC ,RH <85%
11. Dimension:   535mm×440mm×550mm
12. Net weight:   23kg
Â
SYD-265-3 Capillary Viscometer Washer
Summary
    The instrument is designed and made specially for washing the capillary viscometers, which are used for testing petroleum products. It can be used to wash glass capillary viscometer of various types, such as Pinkevitch viscometer, Ubbelohde viscometer, Cannon-Fenske routine viscometer, Cannon-Fenske opaque viscometer. It is high-efficient and time saving especially for the capillary viscometers, which are used for testing heavy oil with high viscosity. Â
    It adopts micro-controller control technology, program control, automatic washing. It needs less solvent oil and it is convenient, efficient. It can be widely used in the enterprises producing and using petroleum products, colleges and universities, and scientific research institutes and so on, where capillary viscometer are used.
Â
I. Main technical specifications
1. Power supply: AC 220V±10%, 50 Hz
2. Maximum power consumption: 700 W
3. Water bath temperature control range: Ambient to 80 ºC
4. Ambient temperature: Room temperature~35ºC
5. Relative humidity: ≤85%
6. Dimension of washer: 320mm×300mm×500mm ( excluding the aspirator )
7. Net weight of washer: 10Kg (excluding the aspirator)
Push-out Metal Baler machine is mainly suitable for steel recovering and processing industries, ferrous and non-ferrous smelt industries:
1) lining plate--Hardox500.
2) bale discharging way is side push-out.
3) designed with quick unit that can improve work efficiency substantially.
4) A new integration design: Avoid secondary installation, convenient for transporation.
5) Hydraulic transmission, compact design, great sealing property.
6) Hydraulic driven with hand-value or PLC, use diesel engine when electrical motor is unavailable.
Push-out Baler, Push-out Baling Machine, Push-out Baling Press, Push-out Baler Equipment, Push-out Metal Compactor
Jiangyin Metallurgy Hydraulic Machinery Factory , https://www.eco-balingmachine.com